visibilityHow to find the pad leak
report Kill power to the equipment before you work at the padThe pump and heater are electric, bonded, and grounded right beside water, so a wet hand on live equipment is a real shock risk. Before you dry joints, snug a union, or open anything, turn the pump and heater OFF at the breaker — not just the timer — and keep the powered parts dry. If the leak is at a pressurized filter or the heater, release the filter's air-relief valve until the gauge reads zero first. If any of this is outside your comfort zone, it's a quick job for a licensed pool tech.
- With the pump running, dry off the pump, filter, heater, and every union and valve with a cloth, then watch which joint re-wets first — a slow weep shows up as a fresh bead or a drip trail.
- Check the same joints again a few minutes after the pump shuts off; some leaks only show under pressure (pump on), others only when it stops.
- Trace any wet, never-drying patch on the pad back to its highest dry point — that's the source. A weeping union or a tired O-ring/gasket is a DIY reseal; a cracked pump or filter housing is a replacement.
buildflashlightbuildpaper towel or dry cloth schedule20 min
handymanHow to fix it
report Power off and pressure released before you open a jointEven a simple union reseal means opening plumbing that may be under pressure, next to a bonded, grounded pump and heater. Turn the pump and heater off at the breaker and release the filter's air-relief valve until the gauge reads zero before you loosen anything — a joint opened under pressure can spray, and a pressurized filter lid can be thrown off with force. Keep the powered equipment dry and don't work on it with wet hands.
With power off at the breaker and any filter pressure released, hand-snug the weeping union or replace its O-ring/gasket with a matching one and a thin film of silicone pool lube, then run the pump and confirm the joint stays dry.
- Switch the pump and heater OFF at the breaker, and if the leak is at or after the filter, open the air-relief valve until the pressure gauge reads zero.
- Try hand-tightening the leaking union nut first — many pad leaks are just a union that has backed off. Never use tools that could crack the plastic.
- If it still weeps, unscrew the union, pull the old O-ring or gasket, wipe the groove clean, and fit a matching new one with a thin film of silicone pool lube (never petroleum grease — it swells the rubber).
- Reassemble hand-tight, restore power, run the pump, and dry the joint and watch it for a few minutes to confirm it stays dry.
schedule30 min savings$8–30
Pool union O-ring / gasket + silicone pool lubeMatch the O-ring or flat gasket to your union/valve size (Hayward/Pentair/Jandy differ); use silicone, not petroleum, lubricant
gavel Vérifiez d’abord votre province AB: permis au propriétaire · BC: permis au propriétaire · ON: permis au propriétaire · PE: permis au propriétaire · QC: permis au propriétaire
The bucket test, pad-union reseal, and vinyl-liner patch are generally owner-permitted across Canada. Bonded/grounded pool-electrical work is licensed per the Canadian Electrical Code (Section 68 pool bonding), and underground-plumbing/shell leak detection is specialist pool-tech work — route both up.