visibilityHow to check
- Slide the filter out of its slot (between the return duct and the furnace) and hold it up to a light. If light won't pass through, that's the prime suspect.
- Time one cycle. An overheating furnace typically runs five to ten minutes, cuts the burners while the blower keeps running, then relights a few minutes later — that pattern points to a limit trip.
- Check the vents around the house too: more than a few closed supply registers, or furniture over the returns, starves airflow just like a clogged filter.
handymanHow to fix it
Fit a new filter of the same size with the airflow arrow toward the furnace, open closed registers, and let the furnace run a full cycle. If it still trips with a clean filter and open vents, book a technician — a limit that keeps tripping has a reason.
- Note the size printed on the old filter's frame (e.g. 16x25x1) and buy the same. Avoid jumping to a much denser filter than the furnace was designed for — that chokes airflow too.
- Slide the new filter in with the airflow arrow pointing toward the furnace, and reseat the panel door.
- Open any closed supply registers and clear the return grilles, then let the furnace run one full cycle: it should now run comfortably past the ten-minute mark.