visibilityHow to check
- With the heating on and the rad calling for heat, run your hand from the bottom of the cold radiator up to the top.
- Warm at the bottom and cold across the top is the signature of trapped air — the air pocket is blocking the top channels.
- Cold top AND bottom instead points elsewhere — check the radiator's valves (a closed or stuck valve) rather than bleeding.
handymanHow to fix it
With a radiator key and a cloth, open the bleed valve at the top of the cold radiator a quarter-turn until the hissing air stops and water trickles out, then close it — and re-check the boiler pressure afterward, topping up if bleeding dropped it.
- Turn the heating off and let the radiators cool a little so you are not working with scalding water, and so the pump is not pushing more air around.
- Fit the radiator key onto the square bleed valve at the top corner of the rad, hold a cloth under it, and turn a quarter-turn counter-clockwise until you hear a steady hiss of escaping air.
- When the hiss stops and a steady trickle of water appears, close the valve snugly (do not overtighten). Wipe up and move to the next cold rad.
- Turn the heating back on and check the boiler pressure gauge — bleeding releases water, so top up with the filling loop if it dropped below the normal band.
Bleeding radiators and topping up boiler pressure are generally owner-permitted across Canada; work on the gas appliance itself is licensed.