visibilityHow to check
- With power still on, turn the dial or thermostat fully down (or to "off"). If the heater keeps running full blast, the switch is not opening — that alone is a strong sign the contacts are welded.
- Switch OFF the breaker for that circuit, verify the heater is dead with a voltage tester, then remove the thermostat cover — a line-voltage thermostat carries the full 240 volts.
- With power off, inspect the contacts for pitting or fused metal, and check continuity across the switch: a thermostat that reads closed (continuous) even in its "off" position has welded contacts and must be replaced.
handymanHow to fix it
Stop it now — go to the electrical panel and switch off the breaker for that circuit so the heater stops drawing power, then keep drapes, furniture, and bedding well clear until it's repaired.
- At the electrical panel, find the breaker for that room's baseboard circuit — it may be labelled by room, or trace it by which breaker stops the heater.
- Switch it fully OFF. Confirm the heater has stopped and is cooling down.
- Pull drapes, furniture, and bedding well clear of the heater, and leave the breaker off until the thermostat or wiring is repaired.
Switching a circuit off at your own panel is not electrical work — it's routine and permitted for any homeowner in every province.