visibilityHow to check
- Check the screen: blank or fading digits point to dead batteries (or, if it has no batteries, to the low-voltage fuse cause further down).
- Check the settings: mode on COOL (not OFF or HEAT) and the setpoint at least 2–3°C below the current room temperature, then wait up to five minutes — many thermostats have a built-in restart delay to protect the compressor.
handymanHow to fix it
Set the mode to COOL, drop the setpoint below room temperature, and replace the batteries if the display is weak. Then give the system five minutes — the compressor restart delay is normal, not a fault.
- Pull the thermostat face off its wall plate (most hinge or slide off) and swap in fresh batteries — usually AA or AAA, printed inside the cover.
- Set mode to COOL and the setpoint 2–3°C below the room temperature so the system gets a clear call for cooling.
- Wait five minutes. If the indoor fan starts and the outdoor unit follows, this was the whole fix.