FirstCheck
EN FR
🍁 Conçu pour les foyers canadiens — rédigé selon les codes canadiens et les règles provinciales. N’est pas destiné à un usage hors du Canada.
ÉBAUCHE — cette page n’a pas encore été révisée par un professionnel licencié. Aperçu éditorial seulement.

Central AC is freezing up (ice on the coil/lines)

A frozen air conditioner looks alarming, but the first move is simple and it's something you can do right now: turn the cooling off, run the fan, and let the ice melt. Most of the time the cause underneath is a cheap airflow problem.

tuneQue remarquez-vous?
Sélectionnez ce qui correspond et la liste ci-dessous se réordonne. Pas certain? Passez.
emergency_home

flag
Commencez ici

In Canada, thaw the system first: set the thermostat to cooling OFF but leave the FAN ON, and give it a few hours to melt all the ice — you can't diagnose a frozen coil, and running it iced can wreck the compressor. Then pull the air filter. A grey, clogged filter is the most common reason an AC freezes up, and a fresh one is under $20. Replace it, then run cooling again and watch whether it re-ices.

Classé selon des données de pannes réelles. L’ordre s’ajuste selon vos observations ci-dessus.

Causes probables, dans l’ordre à vérifier

Ordre typique affiché
Pour débutant Faisable, avec soin Sécurité critique Appelez un pro

handymanHow to fix it

After fully thawing the system, find the filter at the indoor air handler or the return grille, read the size printed on its frame, and slide in a fresh one facing the airflow arrow the right way. Then run cooling and confirm it no longer re-ices.

  1. Make sure the system is fully thawed (cooling OFF, fan ON until the ice is gone) before you close it back up and run cooling again.
  2. Locate the filter slot at the indoor air handler or the large return-air grille, slide out the old filter, and read the size stamped on its cardboard frame (for example 16x25x1).
  3. Insert a matching new filter with the printed airflow arrow pointing toward the unit, restore cooling, and check the coil an hour later — if it stays ice-free, that was it. Set a reminder to check the filter monthly in cooling season.
schedule10 min savings$8–20
Pleated furnace/AC air filterMatch the size stamped on the old filter frame (e.g. 16x25x1) and the MERV rating your system is rated for

verifiedPourquoi confier ceci à un pro

The refrigerant charge is part of the sealed system. In Canada, handling refrigerant requires certification, and a real fix means finding and repairing the leak, not adding gas. This is a licensed HVAC repair — a technician can confirm a low charge quickly and do it legally.

Vos notes accompagnent la demande — ce que vous avez vu, ce que vous avez éliminé, quand ça a commencé — pour que le pro arrive avec une longueur d’avance.

visibilityHow to check

warning Thaw it fully before you open or run anythingTwo things matter here. First, always thaw before diagnosing — cooling OFF, fan ON — because you cannot see a coil under ice, and running the compressor while the coil is frozen can slug it with liquid refrigerant and damage it. Second, when you do open the air handler, cut power at the thermostat and, if in doubt, the furnace/air-handler switch or breaker; the blower can start on its own. Never chip or scrape ice off the coil — the fins are thin aluminum over refrigerant tubing and puncture easily. If a light dusting doesn't restore it, a full coil clean is a fast job for an HVAC tech.
  1. Thaw completely first: set the thermostat to cooling OFF, leave the FAN ON, and wait until every trace of ice on the coil and lines is gone — often a few hours. Do not skip this; a frozen coil can't be read and running it iced can damage the compressor.
  2. Once thawed, turn the system fully off at the thermostat, remove the access panel on the indoor air handler, and shine a light on the evaporator coil (the A-shaped or slab coil of fins).
  3. Look at the fins: clean aluminum with visible gaps means the coil is fine and the trouble is elsewhere; a grey, furry, or matted coat of dust means the coil is choking its own airflow and needs cleaning.
buildflashlight schedule20 min

verifiedPourquoi confier ceci à un pro

Diagnosing and replacing a blower motor means working around line-voltage wiring, a run capacitor that can hold a dangerous charge, and a motor that must be matched to the system. This is a licensed HVAC job — describe the weak or straining fan to a technician and let them confirm it.

Vos notes accompagnent la demande — ce que vous avez vu, ce que vous avez éliminé, quand ça a commencé — pour que le pro arrive avec une longueur d’avance.

sort

Pourquoi la liste est dans cet ordre

Nous ne classons pas seulement selon la probabilité. Nous classons comme le ferait un bon artisan honnête : éliminer d’abord les causes gratuites, sûres et courantes. C’est pourquoi les vérifications peu coûteuses passent avant les réparations chères — et pourquoi tout ce qui est dangereux reçoit un arrêt net plutôt qu’un encouragement. Cet ordre existe pour vous faire économiser, pas pour vous vendre quelque chose.